Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс:
http://earchive.tpu.ru/handle/11683/1248
Полная запись метаданных
Поле DC | Значение | Язык |
---|---|---|
dc.contributor.author | Gogolev, A. S. | en |
dc.contributor.author | Potylitsin, A. P. | en |
dc.date.accessioned | 2015-11-20T02:44:57Z | - |
dc.date.available | 2015-11-20T02:44:57Z | - |
dc.date.issued | 2007 | - |
dc.identifier.citation | Gogolev A. S. Comparison of X-ray sources on the basis of bremsstrahlung and parametric radiations / A. S. Gogolev, A. P. Potylitsin // Bulletin of the Tomsk Polytechnic University. — 2007. — Vol. 311, № 2. — [P. 53-57]. | ru |
dc.identifier.issn | 1684-8519 | - |
dc.identifier.uri | http://earchive.tpu.ru/handle/11683/1248 | - |
dc.description.abstract | The comparative analysis of the X-ray tube and source on the basis of parametric X-ray radiation has been carried out. The parametric X-ray radiation intensity of source on the basis of compact linear accelerator with beam energy of 6 MeV and current of 100 ?A is compared with intensity of ordinary X-ray tube. The performance of slow change of parametric X-ray line energy in a wide range from 6 to 130 keV with line width of about 300 eV may provide the good contrast of received image and decreases the radiation dose | en |
dc.format.mimetype | application/pdf | - |
dc.language.iso | en | en |
dc.publisher | Томский политехнический университет | ru |
dc.relation.ispartof | Bulletin of the Tomsk Polytechnic University. 2007. Vol. 311, № 2 | - |
dc.rights | info:eu-repo/semantics/openAccess | en |
dc.source | Bulletin of the Tomsk Polytechnic University | - |
dc.subject | sources | - |
dc.subject | X-ray radiation | - |
dc.subject | bremsstrahlung | - |
dc.subject | parametric radiations | - |
dc.subject | comparative analysis | - |
dc.subject | X-ray tubes | - |
dc.subject | linear accelerators | - |
dc.subject | energy | - |
dc.subject | current | - |
dc.subject | beams | - |
dc.subject | contrast | - |
dc.subject | images | - |
dc.title | Comparison of X-ray sources on the basis of bremsstrahlung and parametric radiations | ru |
dc.type | Article | en |
dc.type | info:eu-repo/semantics/publishedVersion | en |
dc.type | info:eu-repo/semantics/article | en |
dcterms.audience | Researches | en |
local.description.firstpage | 53 | - |
local.description.lastpage | 57 | - |
local.filepath | http://www.lib.tpu.ru/fulltext/v/Bulletin_TPU/2007/v311eng/i2/15.pdf | - |
local.identifier.bibrec | RU\TPU\book\197949 | - |
local.issue | 2 | - |
local.localtype | Статья | ru |
local.volume | 311 | - |
Располагается в коллекциях: | Известия Томского политехнического университета. Инжиниринг георесурсов |
Файлы этого ресурса:
Файл | Описание | Размер | Формат | |
---|---|---|---|---|
bulletin_tpu-2007-311eng-2-15.pdf | 1,24 MB | Adobe PDF | Просмотреть/Открыть |
Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.