Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://earchive.tpu.ru/handle/11683/132541
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorSednev, Dmitry Andreevichen
dc.contributor.authorSoldatov, Aleksey Ivanovichen
dc.contributor.authorSoldatov, Andrey Alekseevichen
dc.contributor.authorKostina, Maria Alekseevnaen
dc.contributor.authorKoneva, Daria Andreevnaen
dc.date.accessioned2025-09-11T03:35:45Z-
dc.date.available2025-09-11T03:35:45Z-
dc.date.issued2023-
dc.identifier.citationThe Effect of the Position Determination Error for Flexible Linear Array Elements on the Tomogram Focusing / D. A. Sednev, A. I. Soldatov, A. A. Soldatov [et al.] // Sensors. — 2023. — Vol. 23, iss. 10. — [4757, 14 p.].en
dc.identifier.urihttp://earchive.tpu.ru/handle/11683/132541-
dc.description.abstractIn the article, the study of the quality of tomogram focusing during the inspection of objects with curved surfaces by flexible acoustic array was described. The main goal of the study was theoretically and experimentally define the acceptable deviation limits of the elements' coordinates values. The tomogram reconstruction was performed by the total focusing method. The Strehl ratio was chosen as a criterion for assessing the quality of tomogram focusing. The ultrasonic inspection procedure were simulated and validated experimentally by means of convex and concave curved arrays. In the study, it was proven that the elements coordinates of the flexible acoustic array were determined with an error of no more than 0.18? and the tomogram image was obtained in sharp focus.en
dc.format.mimetypeapplication/pdf-
dc.language.isoenen
dc.relation.ispartofSensors. 2023. Vol. 23, iss. 10en
dc.rightsinfo:eu-repo/semantics/openAccess-
dc.rightsAttribution-NonCommercial 4.0 Internationalen
dc.rights.urihttps://creativecommons.org/licenses/by-nc/4.0/-
dc.sourceSensorsen
dc.subjectcurved surfaceen
dc.subjectflexible acoustic arrayen
dc.subjectfocusingen
dc.subjectStrehl ratioen
dc.subjecttotal focusing methoden
dc.subjecttomogramen
dc.subjectwavelengthen
dc.titleThe Effect of the Position Determination Error for Flexible Linear Array Elements on the Tomogram Focusingen
dc.typeArticleen
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dcterms.audienceResearchesen
local.filepathreprint-669525.pdf-
local.filepathhttps://doi.org/10.3390/s23104757-
local.identifier.bibrec(RuTPU)669525-
local.issue10-
local.localtypeСтатьяru
local.volume23-
dc.identifier.doi10.3390/s23104757-
Располагается в коллекциях:Репринты научных публикаций

Файлы этого ресурса:
Файл РазмерФормат 
reprint-669525.pdf5,72 MBAdobe PDFПросмотреть/Открыть


Лицензия на ресурс: Лицензия Creative Commons Creative Commons