Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс:
http://earchive.tpu.ru/handle/11683/34808
Полная запись метаданных
Поле DC | Значение | Язык |
---|---|---|
dc.contributor.author | Aleinik, Aleksandr Nikonorovich | en |
dc.contributor.author | Serikbekova, Z. | en |
dc.contributor.author | Zhukova, N. | en |
dc.contributor.author | Zhukova, I. | en |
dc.contributor.author | Nikitina, M. | en |
dc.date.accessioned | 2016-11-30T17:27:48Z | - |
dc.date.available | 2016-11-30T17:27:48Z | - |
dc.date.issued | 2016 | - |
dc.identifier.citation | Development of an oximeter for neurology / A. N. Aleinik [et al.] // IOP Conference Series: Materials Science and Engineering. — 2016. — Vol. 135 : Issues of Physics and Technology in Science, Industry and Medicine : VIII International Scientific Conference, 1–3 June 2016, Tomsk, Russia : [proceedings]. — [012002, 4 p.]. | ru |
dc.identifier.uri | http://earchive.tpu.ru/handle/11683/34808 | - |
dc.description.abstract | Cerebral desaturation can occur during surgery manipulation, whereas otherparameters vary insignificantly. Prolonged intervals of cerebral anoxia can cause seriousdamage to the nervous system. Commonly used method for measurement of cerebral bloodflow uses invasive catheters. Other techniques include single photon emission computedtomography (SPECT), positron emission tomography (PET), magnetic resonance imaging(MRI). Tomographic methods frequently use isotope administration, that may result inanaphylactic reactions to contrast media and associated nerve diseases. Moreover, the high costand the need for continuous monitoring make it difficult to apply these techniques in clinicalpractice. Cerebral oximetry is a method for measuring oxygen saturation using infraredspectrometry. Moreover reflection pulse oximetry can detect sudden changes in sympathetictone. For this purpose the reflectance pulse oximeter for use in neurology is developed.Reflectance oximeter has a definite advantage as it can be used to measure oxygen saturation inany part of the body. Preliminary results indicate that the device has a good resolution and highreliability. Modern applied schematics have improved device characteristics compared withexisting ones. | en |
dc.language.iso | en | en |
dc.publisher | IOP Publishing | ru |
dc.relation.ispartof | IOP Conference Series: Materials Science and Engineering. Vol. 135 : Issues of Physics and Technology in Science, Industry and Medicine. — Bristol, 2016. | ru |
dc.rights | info:eu-repo/semantics/openAccess | en |
dc.subject | неврология | ru |
dc.subject | компьютерная томография | ru |
dc.subject | оксиметрия | ru |
dc.subject | инфракрасная спектрометрия | ru |
dc.subject | пульсоксиметрия | ru |
dc.title | Development of an oximeter for neurology | en |
dc.type | Conference Paper | en |
dc.type | info:eu-repo/semantics/publishedVersion | en |
dc.type | info:eu-repo/semantics/conferencePaper | en |
dcterms.audience | Researches | en |
local.department | Национальный исследовательский Томский политехнический университет (ТПУ)::Физико-технический институт (ФТИ)::Кафедра прикладной физики (№ 12) (ПФ) | ru |
local.description.firstpage | 12002 | - |
local.filepath | http://dx.doi.org/10.1088/1757-899X/135/1/012002 | - |
local.identifier.bibrec | RU\TPU\network\15467 | - |
local.identifier.colkey | RU\TPU\col\18729 | - |
local.identifier.perskey | RU\TPU\pers\31074 | - |
local.localtype | Доклад | ru |
local.volume | 135 | - |
local.conference.name | Issues of Physics and Technology in Science, Industry and Medicine | - |
local.conference.date | 2016 | - |
dc.identifier.doi | 10.1088/1757-899X/135/1/012002 | - |
Располагается в коллекциях: | Материалы конференций |
Файлы этого ресурса:
Файл | Описание | Размер | Формат | |
---|---|---|---|---|
dx.doi.org-10.1088-1757-899X-135-1-012002.pdf | 937,36 kB | Adobe PDF | Просмотреть/Открыть |
Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.