Please use this identifier to cite or link to this item:
http://earchive.tpu.ru/handle/11683/57039Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Boyakhchyan, A. A. | en |
| dc.contributor.author | Ivanov, Maksim Anatoljevich | en |
| dc.contributor.author | Morenetz, A. I. | en |
| dc.contributor.author | Pavlenko, B. N. | en |
| dc.contributor.author | Torgaev, Stanislav Nikolaevich | en |
| dc.contributor.author | Lezhnina, Inna Alekseevna | en |
| dc.date.accessioned | 2019-11-29T05:21:23Z | - |
| dc.date.available | 2019-11-29T05:21:23Z | - |
| dc.date.issued | 2019 | - |
| dc.identifier.citation | The research of the quality of ECG recording by capacitive electrodes in violation of the skin-electrode contact / A. A. Boyakhchyan [et al.] // Journal of Physics: Conference Series. — 2019. — Vol. 1327 : Innovations in Non-Destructive Testing (SibTest 2019) : V International Conference, 26–28 June 2019, Yekaterinburg, Russia : [proceedings]. — [012046, 5 р.]. | en |
| dc.identifier.uri | http://earchive.tpu.ru/handle/11683/57039 | - |
| dc.description.abstract | This paper presents actual development in the field of personal telemedicine. For personal cardiographs most suitable dry electrodes that do not require a conductive gel. This article describes experiments with capacitive electrodes from Plessey Semiconductors. On the basis of the obtained experimental data, it is planned to create own capacitive electrodes with the possibility of detuning from the skin-electrode contac. | en |
| dc.language.iso | en | en |
| dc.publisher | IOP Publishing | en |
| dc.rights | info:eu-repo/semantics/openAccess | en |
| dc.subject | качество | ru |
| dc.subject | ЭКГ | ru |
| dc.subject | емкостные электроды | ru |
| dc.subject | записи | ru |
| dc.subject | контакты | ru |
| dc.subject | телемедицина | ru |
| dc.subject | кардиология | ru |
| dc.subject | помехоустойчивость | ru |
| dc.title | The research of the quality of ECG recording by capacitive electrodes in violation of the skin-electrode contact | en |
| dc.type | Conference Paper | en |
| dc.type | info:eu-repo/semantics/publishedVersion | en |
| dc.type | info:eu-repo/semantics/conferencePaper | en |
| dcterms.audience | Researches | en |
| local.description.firstpage | 12046 | - |
| local.filepath | https://doi.org/10.1088/1742-6596/1327/1/012046 | - |
| local.identifier.bibrec | RU\TPU\network\31632 | - |
| local.identifier.perskey | RU\TPU\pers\37960 | - |
| local.identifier.perskey | RU\TPU\pers\31663 | - |
| local.identifier.perskey | RU\TPU\pers\33635 | - |
| local.localtype | Доклад | ru |
| local.volume | 13272019 | - |
| local.conference.name | Innovations in Non-Destructive Testing (SibTest 2019) | - |
| local.conference.date | 2019 | - |
| dc.identifier.doi | 10.1088/1742-6596/1327/1/012046 | - |
| Appears in Collections: | Материалы конференций | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| doi.org-10.1088-1742-6596-1327-1-012046.pdf | 855,04 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.