Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс:
http://earchive.tpu.ru/handle/11683/57318
Полная запись метаданных
Поле DC | Значение | Язык |
---|---|---|
dc.contributor.author | Ruban, Nikolay Yurievich | en |
dc.contributor.author | Askarov, Alisher Bakhramzhonovich | en |
dc.contributor.author | Daminova, Ekaterina Sergeevna | en |
dc.date.accessioned | 2020-01-13T06:30:46Z | - |
dc.date.available | 2020-01-13T06:30:46Z | - |
dc.date.issued | 2019 | - |
dc.identifier.citation | Ruban N. Yu. Justification of the double fed induction generator model for estimation of the influence of wind power installations on the operation mode of power systems / N. Yu. Ruban, A. B. Askarov, E. S. Daminova // AIP Conference Proceedings. — 2019. — Vol. 2135 : Heat and mass transfer in the thermal control system of technical and technological energy equipment (HMTTSC 2019) : International Youth Scientific Conference, April 23-25, 2019, Tomsk, Russia. — [020050, 4 p.]. | en |
dc.identifier.uri | http://earchive.tpu.ru/handle/11683/57318 | - |
dc.description.abstract | Mathematical modeling of wind power plants is an urgent task, since the degree of their introduction into traditional energy systems is growing every year. At the same time, it is not always possible to obtain information about the processes in the power system. In such cases, it is possible to use the model of the power system. However, since the power systems are enormous, their model is also great, and therefore, with its detailed reproduction, many problems arise. One solution to such problem is to use simplified wind turbine models. The article substantiates the need to use detailed models of wind turbines to analyze their impact on the functioning of the power system. | en |
dc.language.iso | en | en |
dc.publisher | AIP Publishing | ru |
dc.relation.ispartof | AIP Conference Proceedings. Vol. 2135 : Heat and mass transfer in the thermal control system of technical and technological energy equipment (HMTTSC 2019). — New York, 2019. | ru |
dc.rights | info:eu-repo/semantics/openAccess | en |
dc.subject | индукционные двигатели | ru |
dc.subject | ветроэнергетические установки | ru |
dc.subject | энергосистемы | ru |
dc.title | Justification of the double fed induction generator model for estimation of the influence of wind power installations on the operation mode of power systems | en |
dc.type | Conference Paper | en |
dc.type | info:eu-repo/semantics/publishedVersion | en |
dc.type | info:eu-repo/semantics/conferencePaper | en |
dcterms.audience | Researches | en |
local.description.firstpage | 20050 | - |
local.filepath | https://doi.org/10.1063/1.5120687 | - |
local.identifier.bibrec | RU\TPU\network\30496 | - |
local.identifier.perskey | RU\TPU\pers\34749 | - |
local.identifier.perskey | RU\TPU\pers\43159 | - |
local.identifier.perskey | RU\TPU\pers\44559 | - |
local.localtype | Доклад | ru |
local.volume | 21352019 | - |
local.conference.name | Heat and mass transfer in the thermal control system of technical and technological energy equipment (HMTTSC 2019) | en |
local.conference.date | 2019 | - |
dc.identifier.doi | 10.1063/1.5120687 | - |
Располагается в коллекциях: | Материалы конференций |
Файлы этого ресурса:
Файл | Описание | Размер | Формат | |
---|---|---|---|---|
conf-nw-30496.pdf | 456,93 kB | Adobe PDF | Просмотреть/Открыть |
Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.