Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://earchive.tpu.ru/handle/11683/58054
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorPanin, Sergey Viktorovichen
dc.contributor.authorAntonova, L. V.en
dc.contributor.authorByakov, Anton Viktorovichen
dc.contributor.authorGlushkova, T. V.en
dc.contributor.authorKrivkina, E. O.en
dc.contributor.authorEremin, Alexandr Vyacheslavovichen
dc.contributor.authorSilnikov, V. N.en
dc.contributor.authorBarbarash, L. S.en
dc.date.accessioned2020-03-25T09:03:46Z-
dc.date.available2020-03-25T09:03:46Z-
dc.date.issued2020-
dc.identifier.citationDeformation Behavior under Static and Cyclic Tension of Polymer Grafts without and after Modification by RGD Peptides / S. V. Panin, L. V. Antonova, A. V. Byakov [et al.] // IOP Conference Series: Materials Science and Engineering. — Bristol : IOP Publishing, 2020. — Vol. 731 : Advanced Materials for Engineering and Medicine (AMEM-2019) : International science and technology conference for youth, 30 September-5 October 2019, Tomsk, Russian Federation : [proceedings]. — [012004, 8 p.].en
dc.identifier.urihttp://earchive.tpu.ru/handle/11683/58054-
dc.description.abstractThe structure, mechanical properties, and deformation behavior under static and cyclic tension of biofunctionalized biodegradable vascular grafts based on polyhydroxybutyrate/valerate and polycaprolactone were studied. It is shown that the modification gives rise to an almost twofold decrease of the elongation at break as well as the ultimate strength. It is shown that under cyclic loading the modification of grafts results in decreasing cyclic durability by more than twice. In doing so, the level of deforming stress decreases to a much lesser extent and is practically inferior to that for unmodified material. The analysis of principal strain [epsilon]1 and [epsilon]2 component distribution patterns in grafts of both types is carried out while the reason for the observed changes is discussed.en
dc.language.isoenen
dc.publisherIOP Publishingen
dc.relation.ispartofIOP Conference Series: Materials Science and Engineering. Vol. 731 : Advanced Materials for Engineering and Medicine (AMEM-2019). — Bristol, 2020.en
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.subjectдеформационное поведениеru
dc.subjectрастяжениеru
dc.subjectтрансплантацияru
dc.subjectпрочностьru
dc.subjectтрансплантатыru
dc.subjectрегенерацияru
dc.subjectкровеносные сосудыru
dc.subjectбиоразлагаемые полимерыru
dc.titleDeformation Behavior under Static and Cyclic Tension of Polymer Grafts without and after Modification by RGD Peptidesen
dc.typeConference Paperen
dc.typeinfo:eu-repo/semantics/publishedVersionen
dc.typeinfo:eu-repo/semantics/conferencePaperen
dcterms.audienceResearchesen
local.filepathhttp://dx.doi.org/10.1088/1757-899X/731/1/012004-
local.identifier.bibrecRU\TPU\network\33024-
local.identifier.perskeyRU\TPU\pers\32910-
local.identifier.perskeyRU\TPU\pers\35461-
local.identifier.perskeyRU\TPU\pers\32912-
local.localtypeДокладru
local.volume7312019-
local.conference.nameVol. 731 : Advanced Materials for Engineering and Medicine (AMEM-2019)-
local.conference.date2019-
dc.identifier.doi10.1088/1757-899X/731/1/012004-
Располагается в коллекциях:Материалы конференций

Файлы этого ресурса:
Файл Описание РазмерФормат 
doi.org-10.1088-1757-899X-731-1-012004.pdf1,29 MBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.