Название: Investigation of the effect of condensed phase on the energy conditions for the initiation of the plasma-chemical process of flue gas cleaning by a pulsed electron beam
Авторы: Sazonov, Roman Vladimirovich
Kholodnaya, Galina Evgenievna
Ponomarev, Denis Vladimirovich
Egorov, Ivan Sergeevich
Poloskov, Artem Viktorovich
Serebrennikov, Maksim Anatolevich
Ключевые слова: плазмохимические процессы; импульсные электронные пучки
Дата публикации: 2021
Издатель: IOP Publishing Ltd.
Библиографическое описание: Investigation of the effect of condensed phase on the energy conditions for the initiation of the plasma-chemical process of flue gas cleaning by a pulsed electron beam / R. V. Sazonov, G. E. Kholodnaya, D. V. Ponomarev [et al.] // Journal of Physics: Conference Series. — Bristol : IOP Publishing Ltd., 2021. — Vol. 2064 : Gas Discharge Plasmas and Their Applications (GDP 2021) : 15th International Conference, 5-10 September 2021, Ekaterinburg, Russia. — [012099, 6 p.].
Аннотация: This work investigates the processes of dissipation of the charge and energy of a pulsed electron beam in gas compositions (nitrogen, carbon dioxide and oxygen) in the presence of ammonium sulphate and nitrate. A pulsed electron beam generated by the TEA500 accelerator (Tomsk, Russia) with an electron energy of up to 410 keV, a beam current of up to 5 kA (I0), and a half-amplitude voltage pulse duration of 60 ns was injected into a 46 cm long drift chamber filled with a gas mixture. The pulsed electron beam current (IF?) passing through the drift chamber was registered using a sectioned calorimeter with beam charge monitor function, and the efficiency of the current passage of the beam was determined as the ratio qF?/q0, where q0 is the beam charge measured at the place of its injection into the chamber drift. The pressure in the drift chamber varied (375, 560 and 760 Torr, humidity value 15% ± 5% and 50% ± 5%). The geometric dimensions of the plasma-chemical reactor for initiating plasma-chemical reactions of flue gas cleaning were determined.
URI: http://earchive.tpu.ru/handle/11683/72816
Располагается в коллекциях:Репринты научных публикаций

Файлы этого ресурса:
Файл Описание РазмерФормат 
conf-nw-38308.pdf539,72 kBAdobe PDFПросмотреть/Открыть


Лицензия на ресурс: Лицензия Creative Commons Creative Commons