Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://earchive.tpu.ru/handle/11683/139811
Название: Improving the Reliability of the Protection of Electric Transport Networks
Авторы: Malozemov, Boris Vitaljevich
Khekert, Evgeny Vladimirovich
Martyushev, Nikita Vladimirovich
Konyukhov, Vladimir Yurjevich
Chetverikova, Valentina
Golik, Vladimir Ivanovich
Tynchenko, Vadim Sergeevich
Ключевые слова: electric transport; reliability of operation; current and impulse reliability; current; short circuit; voltage; resistance; setpoint; coverage area
Дата публикации: 2025
Издатель: MDPI AG
Библиографическое описание: Improving the Reliability of the Protection of Electric Transport Networks / Boris V. Malozyomov, Evgeniy V. Khekert, Nikita V. Martyushev [et al.] // World Electric Vehicle Journal. — 2025. — Vol. 16, iss. 8. — Article number 477, 32 p..
Аннотация: In traction networks of mining enterprises, ensuring selective and sensitive protection remains an urgent task, especially in conditions of frequent starts of electric transport and possible cases of short circuits, lack of reliable grounding and increased spreading resistance. Standard methods-maximum current protection (MCP) and differential current protection (DCP)-demonstrate limited efficiency at operating currents less than 800 A, which is typical for remote sections of the contact network. The objective of this study is to develop and experimentally verify a method for adjusting the parameters of current and impulse protection, ensuring reliable shutdown of accidents at low values of short-circuit current without the need to replace equipment. The proposed method is based on transient processes modeled using differential equations and the introduction of a dynamic sensitivity coefficient reflecting the dependence of the setting on the circuit time constant. Universal response characteristics were constructed in normalized coordinates for BAT-49 and VAB-43 switches and RDSh-I and RDSh-II relays. Experiments have confirmed that the application of the method allows for reducing the tripping threshold to 600-650 A, increasing the selectivity of protection to 95% and reducing the probability of false tripping by more than two times compared to MCP/DCP. The response time remained within 35-45 ms, which meets the requirements for high-speed systems. The developed method is adapted to different network sections using the relative coordinates of the energy consumer on the supply section of the traction network and does not require complex digital equipment. This makes it especially effective in field conditions, where it is impossible to upgrade the protection using intelligent adaptive systems
URI: http://earchive.tpu.ru/handle/11683/139811
Располагается в коллекциях:Репринты научных публикаций

Файлы этого ресурса:
Файл РазмерФормат 
reprint-683668.pdf2,27 MBAdobe PDFПросмотреть/Открыть


Лицензия на ресурс: Лицензия Creative Commons Creative Commons