Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс:
http://earchive.tpu.ru/handle/11683/53000
Полная запись метаданных
Поле DC | Значение | Язык |
---|---|---|
dc.contributor.author | Yuzhakov, Mikhail Mikhaylovich | en |
dc.contributor.author | Ivanov, Maxim Leonidovich | en |
dc.contributor.author | Turushev, Nikita Vladimirovich | en |
dc.contributor.author | Maksimov, I. V. | en |
dc.contributor.author | Mazikov, S. V. | en |
dc.contributor.author | Kodermyatov, R. E. | en |
dc.contributor.author | Wenjia, G. | en |
dc.contributor.author | Zimin, I. A. | en |
dc.date.accessioned | 2019-03-19T05:59:08Z | - |
dc.date.available | 2019-03-19T05:59:08Z | - |
dc.date.issued | 2019 | - |
dc.identifier.citation | Research into spontaneous activity of myocardial cells under normal and pathological conditions using the hardware and software complex based on nanosensors / M. M. Yuzhakov [et al.] // IOP Conference Series: Materials Science and Engineering. — Bristol : IOP Publishing, 2019. — Vol. 457 : Modern Technologies for Non-Destructive Testing : VII International Conference, 8–13 October 2018, Tomsk, Russian Federation : [proceedings]. — [012013, 4 p.]. | en |
dc.identifier.uri | http://earchive.tpu.ru/handle/11683/53000 | - |
dc.description.abstract | Cardiovascular diseases are the leading cause of death in the world. The paper focuses on the capability of a nanosensor-based hardware and software complex (HSC) developed at Tomsk Polytechnic University to measure the activity of myocardial cells from the surface of the human body. A comparative study of nanosensors used in the HSC and conventional AgCl electrodes by FIAB Spa (Florence, Italy) was carried out. It is shown that the value of electromagnetic interference in conventional electrodes is several times higher compared to nanosensors. ECG was recorded using the developed HSC in order to show the possibility to control the activity of myocardial cells. | en |
dc.language.iso | en | en |
dc.publisher | IOP Publishing | en |
dc.relation.ispartof | IOP Conference Series: Materials Science and Engineering. Vol. 457 : Modern Technologies for Non-Destructive Testing. — Bristol, 2019. | en |
dc.rights | info:eu-repo/semantics/openAccess | en |
dc.subject | активность | ru |
dc.subject | миокард | ru |
dc.subject | программно-аппаратные комплексы | ru |
dc.subject | наносенсоры | ru |
dc.subject | сердечно-сосудистые заболевания | ru |
dc.subject | помехи | ru |
dc.title | Research into spontaneous activity of myocardial cells under normal and pathological conditions using the hardware and software complex based on nanosensors | en |
dc.type | Conference Paper | en |
dc.type | info:eu-repo/semantics/publishedVersion | en |
dc.type | info:eu-repo/semantics/conferencePaper | en |
dcterms.audience | Researches | en |
local.description.firstpage | 12013 | - |
local.filepath | http://dx.doi.org/10.1088/1757-899X/457/1/012013 | - |
local.identifier.bibrec | RU\TPU\network\28320 | - |
local.identifier.perskey | RU\TPU\pers\36905 | - |
local.identifier.perskey | RU\TPU\pers\34861 | - |
local.identifier.perskey | RU\TPU\pers\32603 | - |
local.localtype | Доклад | ru |
local.volume | 457 | - |
local.conference.name | Modern Technologies for Non-Destructive Testing | - |
local.conference.date | 2018 | - |
dc.identifier.doi | 10.1088/1757-899X/457/1/012013 | - |
Располагается в коллекциях: | Материалы конференций |
Файлы этого ресурса:
Файл | Описание | Размер | Формат | |
---|---|---|---|---|
dx.doi.org-10.1088-1757-899X-457-1-012013.pdf | 1,51 MB | Adobe PDF | Просмотреть/Открыть |
Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.