Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://earchive.tpu.ru/handle/11683/64780
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorLotkov, Aleksandr Ivanovichen
dc.contributor.authorBaturin, Anatoly Anatoljevichen
dc.contributor.authorKopylov, Vladimir Iljichen
dc.contributor.authorGrishkov, Viktor Nikolaevichen
dc.contributor.authorLaptev, Roman Sergeevichen
dc.date.accessioned2021-03-16T04:32:36Z-
dc.date.available2021-03-16T04:32:36Z-
dc.date.issued2020-
dc.identifier.citationStructural Defects in TiNi-Based Alloys after Warm ECAP / A. I. Lotkov, A. A. Baturin, V. I. Kopylov [et al.] // Metals. — 2020. — Vol. 10, iss. 9. — [1154, 11p.].en
dc.identifier.urihttp://earchive.tpu.ru/handle/11683/64780-
dc.description.abstractThe microstructure, martensitic transformations and crystal structure defects in the Ti50Ni47.3Fe2.7 (at%) alloy after equal-channel angular pressing (ECAP, angle 90°, route BC, 1–3 passes at T = 723 K) have been investigated. A homogeneous submicrocrystalline (SMC) structure (grains/subgrains about 300 nm) is observed after 3 ECAP passes. Crystal structure defects in the Ti49.4Ni50.6 (at%) alloy (8 ECAP passes, angle 120°, BC route, T = 723 K, grains/subgrains about 300 nm) and Ti50Ni47.3Fe2.7 (at%) alloy with SMC B2 structures after ECAP were studied by positron lifetime spectroscopy at the room temperature. The single component with the positron lifetime t1 = 132 ps and t1 = 140 ps were observed for positron lifetime spectra (PLS) obtained from ternary and binary, correspondingly, annealed alloys with coarse-grained structures. This t1 values correspond to the lifetime of delocalized positrons in defect-free B2 phase. The two component PLS were found for all samples exposed by ECAP. The component with t2 = 160 ps (annihilation of positrons trapped by dislocations) is observed for all samples after 1–8 ECAP passes. The component with t3 = 305 ps (annihilation of positrons trapped by vacancy nanoclusters) was detected only after the first ECAP pass. The component with t3 = 200 ps (annihilation of positrons trapped by vacancies in the Ti sublattice of B2 structure) is observed for all samples after 3–8 ECAP passes.en
dc.format.mimetypeapplication/pdf-
dc.language.isoenen
dc.publisherMDPI AGen
dc.relation.ispartofMetals. 2020. Vol. 10, iss. 9en
dc.rightsinfo:eu-repo/semantics/openAccess-
dc.rightsAttribution-NonCommercial 4.0 Internationalen
dc.rights.urihttps://creativecommons.org/licenses/by-nc/4.0/-
dc.sourceMetalsen
dc.subjectTiNi-based alloysen
dc.subjectECAPen
dc.subjectmicrostructureen
dc.subjectpositron lifetime spectroscopyen
dc.subjectnanoclustersen
dc.subjectvacanciesen
dc.subjectdislocationsen
dc.titleStructural Defects in TiNi-Based Alloys after Warm ECAPen
dc.typeArticleen
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dcterms.audienceResearchesen
local.description.firstpage1154-
local.filepathreprint-nw-34048.pdf-
local.filepathhttps://doi.org/10.3390/met10091154-
local.identifier.bibrecRU\TPU\network\34048-
local.identifier.perskeyRU\TPU\pers\31884-
local.issue9-
local.localtypeСтатьяru
local.volume10-
dc.identifier.doi10.3390/met10091154-
Располагается в коллекциях:Репринты научных публикаций

Файлы этого ресурса:
Файл Описание РазмерФормат 
reprint-nw-34048.pdf15,11 MBAdobe PDFПросмотреть/Открыть


Лицензия на ресурс: Лицензия Creative Commons Creative Commons