Title: Calcium phosphate coatings produced by radiofrequency magnetron sputtering method
Authors: Bolbasov, Evgeny Nikolaevich
Zheravin, A. A.
Klimov, I. A.
Kulbakin, D. E.
Perelmuter, V. M.
Tverdokhlebov, Sergei Ivanovich
Cherdyntseva, N. V.
Choinzonov, E. L.
Keywords: фосфат кальция; покрытия; магнетронное распыление; титановые имплантаты; гидроксиапатиты
Issue Date: 2016
Publisher: AIP Publishing
Citation: Calcium phosphate coatings produced by radiofrequency magnetron sputtering method / E. N. Bolbasov [et al.] // AIP Conference Proceedings. — 2016. — Vol. 1760 : Physics of Cancer: Interdisciplinary Problems and Clinical Applications 2016 : Proceedings of the International conference, 22-25 March 2016, Tomsk, Russia. — [020006, 5 p.].
Abstract: Calcium phosphate coatings on titanium implants surface, produced by radio frequency (RF) magnetron sputtering method with hydroxyapatite solid target were investigated. It was found that produced coatings are calcium deficient compared to stoichiometric hydroxyapatite. The surface of the coatings is highly rough at the nanoscale and highly elastic. In vivo experiments on rats revealed that titanium implants with the calcium phosphate coatings do not cause negative tissue reaction after 6 months incubation period.