Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://earchive.tpu.ru/handle/11683/57045
Название: Detectability of flat microdefects in radiographic images obtained using linear microfocus bremsstrahlung source based on 18 MeV betatron with narrow target inside
Авторы: Rychkov, Maksim Mikhailovich
Kaplin, Valery Viktorovich
Smolyanskiy, Vladimir Aleksandrovich
Ключевые слова: микродефекты; рентгенография; изображения; микрофокусные источники; тормозные излучения; бетатроны; мишени; микровключения
Дата публикации: 2019
Издатель: IOP Publishing
Библиографическое описание: Rychkov M. M. Detectability of flat microdefects in radiographic images obtained using linear microfocus bremsstrahlung source based on 18 MeV betatron with narrow target inside / M. M. Rychkov, V. V. Kaplin, V. A. Smolyanskiy // Journal of Physics: Conference Series. — 2019. — Vol. 1327 : Innovations in Non-Destructive Testing (SibTest 2019) : V International Conference, 26–28 June 2019, Yekaterinburg, Russia : [proceedings]. — [012014, 6 р.].
Аннотация: For the determination of ability of microfocus Bremsstrahlung (Bs) source based on B-18 betatron to detect flat microgaps and microinclusions in heavy material products the investigations were carried out. The radiographic images of 10 [mu]m gaps and 13 [mu] m tantalum (Ta) foil into steel bulk which were oriented at different angles with respect to the direction of radiation were investigated. The assembly of four steel blocks having 10 [mu]m gaps between their neighbor surfaces was placed on goniometer. The 13 [mu]m Ta foil having the length of 4 mm along radiation beam was mounted in a plastic holder which was also placed on the goniometer. For modeling narrow gaps and thin inclusions inside the bulk of steel detail, the experimental samples were placed before a thick steel plate. The radiographic images of the samples were obtained with a 2.4-fold magnification at different orientations of narrow gaps and Ta foil with respect to the radiation beam and at the thick steel plates of different thicknesses. The results illustrate high sensitivity of detecting of the microgaps inside steel bulk and flat microinclusions from heavy material in the bulk of detail made from a lighter material due to the microfocus of Bs source.
URI: http://earchive.tpu.ru/handle/11683/57045
Располагается в коллекциях:Материалы конференций

Файлы этого ресурса:
Файл Описание РазмерФормат 
doi.org-10.1088-1742-6596-1327-1-012014.pdf745,88 kBAdobe PDFПросмотреть/Открыть