Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс:
http://earchive.tpu.ru/handle/11683/139813| Название: | Analysis of Air Exchange System Influence on Thermal and Concentration Modes in the Local Working Area under Radiant Heating Conditions |
| Авторы: | Borisov, Boris Vladimirovich Kuznetsov, Geny Vladimirovich Maksimov, Vyacheslav Ivanovich Nagornova, Tatiana Aleksandrovna Salikhov, Feliks Yurjevich |
| Ключевые слова: | gas infrared heater; air exchange system; local working areas; temperature fields; CO2 concentration fields |
| Дата публикации: | 2024 |
| Издатель: | Global Digital Central |
| Библиографическое описание: | Analysis of Air Exchange System Influence on Thermal and Concentration Modes in the Local Working Area under Radiant Heating Conditions / Boris Borisov, Geniy Kuznetsov, Vyacheslav Maksimov [et al.] // Frontiers in Heat and Mass Transfer (FHMT). — 2024. — Vol. 22, iss. 6. — P. 1597-1612. |
| Аннотация: | This study deals with the numerical investigation of combined heat transfer via conduction, laminar natural convection, and surface radiation in a closed rectagular cavity with a radiant heating source. Unsteady two-dimensional equations of mass, momentum, and energy conservation for complex heat transfer process under study were formulated in terms of the vorticity - stream function - temperature variables and solved by means of the finite difference method on a uniform grid. Developed numerical code was validated against two benchmark problems of convective and convective-radiative heat transfer. When analyzing complex heat transfer regularities, we varied the following parameters: dimensionless time 5<t<800, Rayleigh number 6*10^4<Ra<4*10^6, conduction-radiation number 19.71<Nr<78.84, surface emissivity 0.2<e<0.9, emitter length 0.1<D<1, walls thickness 0.05<M<0.25. According to the results of mathematical modelling, it was found that the radiant parameters significantly affected the formation of differential and integral characteristics of conjugate heat transfer. Along with that the convective Nusselt number was slightly changed in geometrical and physical conditions under study. An increase in the walls thickness led to a reduce in the temperature of the air cavity. However, the effect of wall thickness on the convective and radiative Nusselt numbers was not significant |
| URI: | http://earchive.tpu.ru/handle/11683/139813 |
| Располагается в коллекциях: | Репринты научных публикаций |
Файлы этого ресурса:
| Файл | Размер | Формат | |
|---|---|---|---|
| reprint-683801.pdf | 1,11 MB | Adobe PDF | Просмотреть/Открыть |
Лицензия на ресурс: Лицензия Creative Commons