Please use this identifier to cite or link to this item:
http://earchive.tpu.ru/handle/11683/132558
Title: | An Optical Measuring Transducer for a Micro-Opto-Electro-Mechanical Micro-g Accelerometer Based on the Optical Tunneling Effect |
Authors: | Barbin, Evgeny Sergeevich Nesterenko, Tamara Georgievna Koleda, Aleksey Nikolaevich Shesterikov, Evgeny Viktorovich Kulinich, Ivan Kokolov, Andrey Aleksandrovich |
Keywords: | акселерометры; оптические измерительные приборы; оптические преобразователи; инерционная масса; волноводы; пороговая чувствительность; MOEM-accelerometer; optical measuring transducer; inertial mass; movable and fixed waveguides; optical transmission coefficient; coupling length; threshold sensitivity; directional coupler; silicon-on-insulator (SOI) |
Issue Date: | 2023 |
Citation: | An Optical Measuring Transducer for a Micro-Opto-Electro-Mechanical Micro-g Accelerometer Based on the Optical Tunneling Effect / E. S. Barbin, T. G. Nesterenko, A. N. Koleda [et al.] // Micromachines. — 2023. — Vol. 14, iss. 4. — [802, 22 p.]. |
Abstract: | Micro-opto-electro-mechanical (MOEM) accelerometers that can measure small accelerations are attracting growing attention thanks to their considerable advantages-such as high sensitivity and immunity to electromagnetic noise-over their rivals. In this treatise, we analyze 12 schemes of MOEM-accelerometers, which include a spring mass and a tunneling-effect-based optical sensing system containing an optical directional coupler consisting of a fixed and a movable waveguide separated by an air gap. The movable waveguide can perform linear and angular movement. In addition, the waveguides can lie in single or different planes. Under acceleration, the schemes feature the following changes to the optical system: gap, coupling length, overlapping area between the movable and fixed waveguides. The schemes with altering coupling lengths feature the lowest sensitivity, yet possess a virtually unlimited dynamic range, which makes them comparable to capacitive transducers. The sensitivity of the scheme depends on the coupling length and amounts to 11.25 × 103 m−1 for a coupling length of 44 μm and 30 × 103 m−1 for a coupling length of 15 μm. The schemes with changing overlapping areas possess moderate sensitivity (1.25 × 106 m−1). The highest sensitivity (above 6.25 × 106 m−1) belongs to the schemes with an altering gap between the waveguides. |
URI: | http://earchive.tpu.ru/handle/11683/132558 |
Appears in Collections: | Репринты научных публикаций |
Files in This Item:
File | Size | Format | |
---|---|---|---|
reprint-669642.pdf | 12,07 MB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License