Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс:
http://earchive.tpu.ru/handle/11683/132558
Название: | An Optical Measuring Transducer for a Micro-Opto-Electro-Mechanical Micro-g Accelerometer Based on the Optical Tunneling Effect |
Авторы: | Barbin, Evgeny Sergeevich Nesterenko, Tamara Georgievna Koleda, Aleksey Nikolaevich Shesterikov, Evgeny Viktorovich Kulinich, Ivan Kokolov, Andrey Aleksandrovich |
Ключевые слова: | акселерометры; оптические измерительные приборы; оптические преобразователи; инерционная масса; волноводы; пороговая чувствительность; MOEM-accelerometer; optical measuring transducer; inertial mass; movable and fixed waveguides; optical transmission coefficient; coupling length; threshold sensitivity; directional coupler; silicon-on-insulator (SOI) |
Дата публикации: | 2023 |
Библиографическое описание: | An Optical Measuring Transducer for a Micro-Opto-Electro-Mechanical Micro-g Accelerometer Based on the Optical Tunneling Effect / E. S. Barbin, T. G. Nesterenko, A. N. Koleda [et al.] // Micromachines. — 2023. — Vol. 14, iss. 4. — [802, 22 p.]. |
Аннотация: | Micro-opto-electro-mechanical (MOEM) accelerometers that can measure small accelerations are attracting growing attention thanks to their considerable advantages-such as high sensitivity and immunity to electromagnetic noise-over their rivals. In this treatise, we analyze 12 schemes of MOEM-accelerometers, which include a spring mass and a tunneling-effect-based optical sensing system containing an optical directional coupler consisting of a fixed and a movable waveguide separated by an air gap. The movable waveguide can perform linear and angular movement. In addition, the waveguides can lie in single or different planes. Under acceleration, the schemes feature the following changes to the optical system: gap, coupling length, overlapping area between the movable and fixed waveguides. The schemes with altering coupling lengths feature the lowest sensitivity, yet possess a virtually unlimited dynamic range, which makes them comparable to capacitive transducers. The sensitivity of the scheme depends on the coupling length and amounts to 11.25 × 103 m−1 for a coupling length of 44 μm and 30 × 103 m−1 for a coupling length of 15 μm. The schemes with changing overlapping areas possess moderate sensitivity (1.25 × 106 m−1). The highest sensitivity (above 6.25 × 106 m−1) belongs to the schemes with an altering gap between the waveguides. |
URI: | http://earchive.tpu.ru/handle/11683/132558 |
Располагается в коллекциях: | Репринты научных публикаций |
Файлы этого ресурса:
Файл | Размер | Формат | |
---|---|---|---|
reprint-669642.pdf | 12,07 MB | Adobe PDF | Просмотреть/Открыть |
Лицензия на ресурс: Лицензия Creative Commons